For chin bone harvests, notably for the mental foramen and mandibular ramus. For general bone surgery.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Five teeth ; 0.6 mm thick
For chin bone harvests, notably for the mental foramen and mandibular ramus. For general bone surgery.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Five teeth ; 0.6 mm thick
For chin bone harvests, notably for the mental foramen and mandibular ramus. For general bone surgery.
For use in deeper regions requiring longer tips.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6, 9, 12 and 15 mm from tip end
• Five teeth ; 0.6 mm thick
For excisions in areas with inclines or projections or which are otherwise hard to access with SG1 and other regular tips.
• POWER LEVEL [SURG] 80%
• TiN coating
• Right curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
For excisions in areas with inclines or projections or which are otherwise hard to access with SG1 and other regular tips.
• POWER LEVEL [SURG] 80%
• TiN coating
• Left curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
For clinical cases where movement is restricted around the end of the tip.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Three teeth ; 0.6 mm thick
For clinical cases where movement is restricted around the end of the tip.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Three teeth ; 0.6 mm thick
For clinical cases where movement is restricted around the end of the tip.
For use in deeper regions requiring longer tips.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6, 9, 12 and 15 mm from tip end
• Three teeth ; 0.6 mm thick
For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• 90 degree right curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• 90 degree left curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 80%
• TiN coating
• 90 degree right curved tip*
• Five teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 80%
• TiN coating
• 90 degree left curved tip*
• Five teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
For excisions in areas with inclines or projections or which are otherwise hard to access with SG1 and other regular tips.
For cutting curved surfaces.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dot mark 3 mm from tip end
• Five teeth ; 0.8 mm thick
For regions that are hard to access with regular tips, notably the posterior mandible or curved areas.
For narrow cutting to reduce bone loss. Also suitable for corticotomies.
• POWER LEVEL [SURG] 50%
• TiN coating
• Sharp edge
• 0.5 mm thick
For regions that are hard to access with regular tips, notably the posterior mandible or curved areas.
For removing tori on the posterior mandible or mandibular lingual surface.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Three teeth ; 0.6 mm thick
Unilateral anterior mandibular sampling
Excision of bone torus
Anterior mandibylar harvesting
Mandibular harvesting at approach stage
The cutting part is bone torus